If you need AC frozen coil repair in Parker, CO, you may see ice on the copper line outside or frost on the indoor coil. The AC runs but cools poorly. A frozen coil is a symptom. Something is stopping heat from reaching the coil, and that needs to be found.

Call (303) 647-3227

Common causes

✓

Poor airflow. Closed vents, blocked returns or a weak blower let the coil get too cold.

✓

Dirty filter. The most common cause of poor airflow.

✓

Low refrigerant. A leak drops the coil pressure and temperature below freezing.

✓

Dirty evaporator coil. Dust on the coil stops heat transfer.

What to check first

✓

Turn the AC off at the thermostat. Set the fan to ON to help thaw the coil.

✓

Replace the filter.

✓

Open supply vents and clear return grilles.

✓

Put towels down. Melting ice can overflow the drain pan.

✓

Let the coil thaw fully, which can take several hours, before you turn cooling back on.

Do not chip or scrape ice off the coil. The fins and tubing are easy to damage.

When to call for a frozen AC coil

If the coil freezes again after a new filter and full thaw, call. Repeat freezing usually means low refrigerant or a blower problem. Running a frozen AC can damage the compressor. In Parker, Colorado, the dry air hides moisture problems, so ice is often the first sign anything is wrong.

A contractor can check airflow, measure refrigerant pressure and look for a leak if the charge is low.

1.

You call the line and describe what the system is doing.

2.

Your call goes to an independent local HVAC contractor who serves Parker.

3.

The contractor asks a few questions and sets up a visit that suits you.

Frequently asked questions

Why does my AC coil keep freezing?

Poor airflow from a dirty filter is the most common reason. If the filter is clean, low refrigerant or a weak blower is likely.

Usually a few hours with the cooling off and the fan on. Heavy ice can take longer.

No. It will not cool well and can damage the compressor. Turn cooling off until the coil thaws and the cause is found.

Talk to a local HVAC contractor

Coil icing up again? Call (303) 647-3227. We connect you with an independent local HVAC contractor who handles frozen AC coils in Parker.

Call (303) 647-3227

Next Step

Ice on the AC?

Call to reach an independent local HVAC contractor in Parker.

Call Now

☎ (303) 647-3227

Start Here

Get HVAC help in Parker today

One call connects you with an independent local HVAC contractor. They can talk through the problem with you and arrange a visit.

Call (303) 647-3227